Diemazz

Japji
Nozato Station
Temperature gradient
Stratford, California
Li Jing
Ice age
ajeeb translation
Video sharing
Ceylonese
Dou Huaizhen
State leaders by year
Beer in Serbia
Jay Z
local 455
Category:French films
Category:Mersin Province
Minokamo, Gifu
Condrò
Retroactive overtime
Jean Baptiste Lemoyne
Category:Yokozuna
exemplum
Marketplace
Serianthes
t50t
Tarar
Jean Baptiste Tuby
Category:People from Lyon
History of the Maldives
Jules Clément Chaplain
Bitumen
Category:1518 births
CargoNet
Soapbox on MSN Video
Mumun
WQLH
Mojohan
Yang Guo
List of political parties in Grenada
WAUB
Category:India ethnic group templates
Vladimir Mikhailov
Grevesmڶhlen
Kuguno, Gifu
KAQD
Pont des Arts
t203t
CSS Profile
Category:Scots language
Zheng Xunyu
Gifu City Women's College
Beast poetry
Prince Kan'in
mpeg 1
gokkun


Unibus
Unibus
Created by: Digital Equipment Corporation
Hotplugging? no
External? no

The Unibus was the earliest of several bus technologies used with PDP-11 and early VAX systems manufactured by the Digital Equipment Corporation of Maynard, Massachusetts.

The Unibus was composed of 72 wires (2 connectors x 36 lines per connector). When not counting the power and ground lines, it is usually referred to as a 56 line bus. It could exist within a backplane or on a cable. Up to 20 nodes (devices) could be connected to a single Unibus segment; additional segments could be connected via a bus repeater.

The bus was completely asynchronous, allowing a mixture of fast and slow devices. It allowed the overlapping of arbitration (selection of the next bus master) while the current bus master was still performing data transfers. The 18 address lines allowed the addressing of a maximum of 256 kB.[1] Typically, the top 8 kB was reserved for the registers of the memory mapped IO devices used in the PDP-11 architecture.

The design deliberately minimized the amount of redundant logic required in the system. For example, a system always contained more slave devices than master devices so most of the fancy logic required to implement asynchronous data transfers was forced into the relatively few master devices. For interrupts, only the interrupt-fielding processor needed to contain the complicated timing logic. The end result was that most I/O controllers could be implemented with very simple logic and most of the critical logic was implemented as a custom MSI IC.

18 A00-A17 - Address Lines
16 D00-D15 - Data Lines
 4 BR4-BR7 - Bus (Interrupt) Requests at priorities 4 (lowest) through 7 (highest)
 4 BG4-BG7 - Bus (Interrupt) Grants at priorities 4 (lowest) through 7 (highest)
 1 NPR     - Non Processor (DMA) Request
 1 NPG     - Non Processor (DMA) Grant
 1 ACLO    - AC Low
 1 DCLO    - DC Low
 1 MSYNC   - Master Sync
 1 SSYNC   - Slave Sync
 1 BBSY    - Bus Busy
 1 SACK    - Selection Acknowledge
 1 INIT    - Bus Init
 1 INTR    - Interrupt Request
 1 PA      - Parity control
 1 PB      - Parity control
 2 C0-C1   - Cyce Control Lines:
 2 +5v     - Power Lines (not counted as part of the 56)
14 Gnd     - Ground Lines (not counted as part of the 56)

The two control lines (C0 and C1) allowed the selection of four different data transfer cycles:

  • DATI (Data In, a read)
  • DATIP (Data In/Pause, the first portion of a Read-Modify-Write operation. A DATO or DATOB operation completes this.)
  • DATO (Data Out, a word write)
  • DATOB (Data Out/Byte, a byte write)
  • During an interrupt cycle, a fifth style of transfer was automatically invoked to convey an interrupt vector from the interrupting device to the interrupt-fielding processor.

References